Manufacturing

Sterile fill and oral solid dose, packaged in-house

Two production streams — sterile injectables and oral solids — feed a single serialised packaging line. Classified cleanrooms, qualified equipment and continuous environmental monitoring sit behind every monograph in the register.

Facility · cleanroomsGrade A–D
Grade A
ISO 4.8
Grade B
ISO 5
Grade C
ISO 7 / 8
Grade D
ISO 8
Positive-pressure cascade0.36–0.54 m/s

A classified facility with segregated streams for sterile injectables and oral solids, built around Grade A–D cleanrooms and a Water-for-Injection loop.

A–D
Cleanroom grades
WFI
Water-for-injection loop
24/7
Environmental monitoring
IQ·OQ·PQ
Equipment qualified

Cleanroom grades (EU GMP Annex 1)

Grade A — filling & aseptic connections
ISO 4.8 · unidirectional 0.36–0.54 m/s
Grade B — aseptic background
ISO 5 (at rest)
Grade C — preparation
ISO 7 / ISO 8
Grade D — support
ISO 8 (at rest)

HVAC & air handling

Supply air
HEPA-filtered (H14, ≥ 99.995%)
Grade A airflow
Unidirectional, 0.36–0.54 m/s
Pressure cascade
Positive, ~10–15 Pa between grades
Air changes (Grade B)
≥ 20 per hour
Recovery
Cleanroom recovery time verified at requalification

Water systems

Purified Water (PW)
Ph. Eur. grade, circulating loop
Water-for-Injection (WFI)
Distillation; hot circulation ≥ 70 °C
Monitoring
Conductivity, TOC, bioburden, endotoxin
Endotoxin (WFI)
≤ 0.25 EU/ml (USP <85>)

Environmental monitoring

  • Non-viable particle counts (≥ 0.5 µm and ≥ 5.0 µm) at defined locations.
  • Viable air sampling, settle plates and contact plates on a risk-based schedule.
  • Personnel monitoring (glove and gown) after aseptic interventions.
  • Continuous differential-pressure, temperature and humidity logging with alarms.

Personnel & flow

  • Segregated personnel and material airlocks into each grade.
  • Qualified aseptic gowning with periodic gown re-qualification.
  • Unidirectional material flow from dispensing through to packing.
  • Aseptic process simulations (media fills) qualify the filling operation.

Utilities

Purified Water and Water-for-Injection are generated and distributed through monitored loops; HVAC maintains classified pressure cascades. All critical utilities and equipment are commissioned through Installation, Operational and Performance Qualification (IQ/OQ/PQ).

Particle and viable limits are given in full on the Cleanroom & CCS tab, following EU GMP Annex 1 (2022 revision) and ISO 14644-1:2015. Figures are illustrative of the facility standard, not a specific site certification.